Part Number |
Name/Description |
Software Version |
Affiliate |
Tech Details |
Special Notes |
|
|
|
|
|
|
Absima |
2110011 |
Revenge CTS 10 V2 |
B358105 |
Bellgate Distributors |
|
Green LED 0.42 seconds/flash Use Programming Box to set Boost Timing and Turbo Timing to 0deg. |
Calandra Racing Concepts |
CRC4000 |
Advanced Electronics Black Diamond LV |
2.1 software or higher |
Calandra Racing Concepts |
|
Has a blinking blue light when the throttle is in neutral and when set to the no-timing profile #1 |
CRC4002 |
Advanced Black Diamond |
2.1 software or higher |
|
|
Has a blinking blue light when the throttle is in neutral and when set to the no-timing profile #1 |
Castle Creations |
|
Mamba Max Pro |
V1.26 |
|
|
|
010-0155-00 |
Mamba X |
V 2.02 (Beta) |
Castle Creations |
|
Yellow LED 0.39 seconds/flash How to Activate Non-Timing Operation: Use Castle Link PC program and USB adapter to select |
ELCERAM |
NITRIDE001 |
NITRIDE 1/10 ESC |
|
ELCERAM a.s. |
|
ZERO TIMING MODE IS SET VIA DISPLAY AND BUTTONS ON FACE OF ESC. WHEN IN ZERO TIMING MODE. APPROVAL DATE - SEPTEMBER 4TH, 2023 |
OXIDE |
Elceram OXIDE |
Default - as Shipped |
ELCERAM a.s. |
Details |
Blinky / ZERO Timing / Stock Displayed when in "Blinky" Mode |
Fantom Racing |
FAN24040 |
FR-10 Pro 2S 160A Black Edition |
V4.21_00000000 |
Fantom Racing |
|
Blue LED 0.66 seconds/flash How to Activate Non-Timing Operation: Use Program Card to set "G5: RACE MODE" to "Stock", or set "T1: BOOST TIMING" and "T4: TURBO TIMING" to 0deg. |
FAN24045 |
FR-1S Pro 160A |
V4.21_00000000 |
Fantom Racing |
|
Blue LED 0.66 seconds/flash How to Activate Non-Timing Operation: Use Program Card to set "G5: RACE MODE" to "Stock", or set "T1: BOOST TIMING" and "T4: TURBO TIMING" to 0deg. |
FAN24050 |
Fantom Racing FR-10 Pro |
FM-Code-5.1 |
Fantom Racing |
|
Blue LED 0.66 seconds/flash How to Activate Non-Timing Operation: Use Program Card to set |
G Force |
G0011 |
TS120 Series, Model #G0011 |
2.02 |
Hobby Authority Distribution / Maclan |
|
Red LED 0.184seconds/flash. Use programming box to set "Boost Timing" and Turbo Timing" to zero |
G0089 |
G Force Model TS50 |
1.05 |
Hobby Authority Distribution / Maclan |
|
Always in non-timing mode. No timing options available |
Hobbywing |
30112003 |
Xerun XR10 Justock G3 |
XR-4.1.11 |
Hobbywing Technology Co. Ltd. |
|
Red LED 0.26 seconds / flash. Always in no timing mode. |
30112005 |
Hobbywing XERUN XR10 Justock G3S |
XR-4.4.01 |
Hobbywing Technology Co. Ltd. |
|
Steady Red Blink at Neutral / Always Non-Timing 2542B 100MHz - 1GS/a |
30112005 |
XERUN Justock G3S |
Hardware Ver. HW4114SD_V1.1, Software Version XR-4.4.03 |
Hobbywing Technology Co. Ltd. |
|
Always in Non-Timing Mode, Steady Red Blinking LED. .006ms@100 |
30112101001 |
Xerun-120A V3.1 Stock Spec |
V3.1_121129_Beta |
Hobbywing Technology Co. Ltd. |
|
Activate non-timing w/program box to Profile 2. Red LED, 0..31 seconds/flash |
30112121051 |
Xerun-120A-1S-V3.1 |
V3.1_121129_Beta |
Hobbywing Technology Co. Ltd. |
|
Activate non-timing w/program box to Profile 2. Red LED, 0.28 seconds/flash |
30112401 |
XR10 Stock Spec |
XR-4.2.05 |
Hobbywing Technology Co. Ltd. |
|
Red LED rapidly flashes, then pauses, repeats. How to Activate Non-Timing Operation: Use Program Box to set Mode to "Zero Timing" then set Boost Timing, Turbo Timing, Softening Value and Softening Range to zero. |
30112402 |
XERUN XR10 Stock Spec G2 |
XR-4.3.01 - PB-1.0.15 - APPPROVED 01/18/2024 |
Hobbywing Technology Co. Ltd. |
|
Turbo, Boost and Softening Must be at 0. Rapid Red blink, pause, rapid red blink, pause is LED sequence for 0 timing mode |
30112402 |
XERUN Stock Spec G2 |
Hrdware Ver. HW4120SD_V1.0, Software Ver. XR-4.3.02 |
Hobbywing Technology Co. Ltd. |
|
0 Values for Softening. ESC does not offer Timing. NO SOFTENING ALLOWED. Blinking Red LED, Pause, Blinking Red LED .055ms @ 100 |
30112600,30112601, 30112602 |
XR10 Pro |
XR-4.3.05 |
Hobbywing Technology Co. Ltd. |
|
Red LED rapidly flashes, then pauses, repeats. How to Activate Non-Timing Operation: Use Program Box to set Mode to "Zero Timing" then set Boost Timing, Turbo Timing, Softening Value and Softening Range to zero. |
30112606,30112607, 30112608, 30112610 |
XR10 Pro G2 |
XR-4.4.12 |
Hobbywing Technology Co. Ltd. |
|
Red LED rapidly flashes, then pauses, repeats. How to Activate Non-Timing Operation: Use Program Box to set Mode to "Zero Timing" then set Boost Timing, Turbo Timing, Softening Value and Softening Range to zero. |
30112609 |
XERUN XR 10 Pro 1S HD |
XR-4.2.05 |
Hobbywing Technology Co. Ltd. |
|
Red LED rapidly flashes, then pauses, repeats. How to Activate Non-Timing Operation: Use Program Box to set Mode to "Zero Timing" then set Boost Timing, Turbo Timing, Softening Value and Softening Range to zero. |
30112613 /30112617 |
XERUN XR 10 Pro G2S |
XR-5.0.05 |
Hobbywing Technology Co. Ltd. |
|
Red LED rapidly flashes, then pauses, repeats. How to Activate Non-Timing Operation: Use Program Box to set Mode. Note unique blink pattern for approved software |
30112619 |
XERUN XR10 PRO - G3 |
XR-6.1.00 |
Hobbywing Technology Co. Ltd. |
Details |
BOOST, TIMING AND SOFTENING ALL ZERO. LED BLINKS THREE TIMES, PAUSES AND REPEATS |
30112620 |
XERUN XR10 PRO - G3-X |
XR-6.1.00 |
Hobbywing Technology Co. Ltd. |
Details |
BOOST, TIMING AND SOFTENING ALL ZERO. LED BLINKS THREE TIMES, PAUSES AND REPEATS |
30112751 |
XR10 Stock Spec 1S |
XR-4.2.05 |
Hobbywing Technology Co. Ltd. |
|
Red LED rapidly flashes, then pauses, repeats. How to Activate Non-Timing Operation: Use Program Box to set Mode to "Zero Timing" and set Boost Timing and Turbo Timing to zero. |
81020000(blue) or 81020011(black) |
Justock Club SPEC |
N/A |
|
|
Zero timing and non-adjustable |
81020010(blue) or 81020011(black) |
Xtreme Stock |
508 |
|
|
Zero timing - the RED LED Flashes when the ESC is active and throttle in neutral position. |
81020050 |
Xerun 60A-SD V2.1 (Blue) |
508 |
|
|
Zero timing - the RED LED Flashes when the ESC is active and throttle in neutral position. |
81020051 |
Xerun 60A-SD V2.1 (Black) |
508 |
|
|
Zero timing - the RED LED Flashes when the ESC is active and throttle in neutral position. |
81020170 |
Xerun 120A-SD V2.1 (Blue) |
508 |
|
|
Zero timing - the RED LED Flashes when the ESC is active and throttle in neutral position. |
81020171 |
Xerun 120A-SD V2.1 (Black) |
508 |
|
|
Zero timing - the RED LED Flashes when the ESC is active and throttle in neutral position. |
81020210 |
Xerun 120A-1S (Black) |
508 |
|
|
Zero timing - the RED LED Flashes when the ESC is active and throttle in neutral position. |
81020211 |
Xerun 120A-1S (Blue) |
508 |
|
|
Zero timing - the RED LED Flashes when the ESC is active and throttle in neutral position. |
81020310 81020320 81020330 |
XERUN-120A V3 |
Software V3.1_121129_beta |
|
|
ESC must use Profile #2, red LED on power button flashes when throttle is at neutral in non-timing mode |
81020340 81020350 81020360 |
XERUN-120A V3.1 |
Software V3.1_121129_beta |
|
|
ESC must use Profile #2, red LED on power button flashes when throttle is at neutral in non-timing mode |
SKU) 30112000 |
Justock Model XR10 |
V1_509_No Timing |
Hobbywing Technology Co. Ltd. |
|
Red LED 0.26 seconds/flash. Always in Non-Timing mode |
KO Propo |
40051 |
VFS-1 BMC Ver 1.5 |
Contact Mfg for Firmware Upgrade |
|
|
Must use zero timing and zero Advanced Profile signified by blinking LED on switch. |
KO PROPO America |
4100 |
BLZ-350 ESC |
|
|
|
Set to zero timing in firware. Cannot program any timing into ESC |
Losi |
LOSB9500 |
1/10th Xcelorin Brushless ESC |
01.01.30 |
|
|
Must use zero timing and zero Advanced Profile signified by blinking color LED |
LOSB9503 |
MSC540BL-S Sensored ESC, 13.5T Limit |
|
|
|
There is no timing function available with this. There is no LED indication. |
LRP |
500004 |
Flow X TC Spec |
v4.1 |
Lautenbach Racing Products - LRP / Nosram |
|
Blue LED 1.30 seconds/flash How to Activate Non-Timing Operation: Press MODE button until red LED flashes, then release button. Press and release MODE button five more times to make blue and red LEDs flash. Press and release SET button until green LED does not flash. Press and re |
500003 |
Flow X Offroad |
v3.1 |
Lautenbach Racing Products - LRP / Nosram |
|
Blue LED 1.30 seconds/flash How to Activate Non-Timing Operation: Press MODE button until red LED flashes, then release button. Press and release MODE button five more times until blue and red LEDs flash. Press and release SET button until green LED does not flash. Press and release MODE button four more times. |
500005 |
Flow X Stock Spec |
v5.1 |
Lautenbach Racing Products - LRP / Nosram |
|
Blue LED 1.30 seconds/flash. Press MODE button until red LED flashes, then release button. Press and release MODE button five more times until blue LED flashes. Press and release SET button until green LED does not flash. Press and release MODE button once to make blue and red LEDs flash. Press and release SET button until green LED does not flash. Press and release MODE button two more times. |
80960 |
Flow Competition Software 5.4 |
5.4 |
Lautenbach Racing Products - LRP / Nosram |
|
Blue LED 1.30 seconds/flash. Non Timing: Set torque timing (Mode5) and Boost Timing (Mode 6) to zero |
80970 |
Flow Works Team Software 5.4 |
5.4 |
Lautenbach Racing Products - LRP / Nosram |
|
Blue LED 1.30 seconds/flash. Non Timing: Set torque timing (Mode5) and Boost Timing (Mode 6) to zero |
LRP80100 |
Ai Brushless Reverse |
N/A |
|
|
Non-updateable; SC has no modes that will give any timing increase. |
LRP80150 |
Ai Brushless Pro Reverse |
N/A |
|
|
Non-updateable; SC has no modes that will give any timing increase. |
LRP80400 |
SPX Brushless Super Reverse |
N/A |
|
|
Non-updateable; SC has no modes that will give any timing increase. |
LRP80410 |
Crawler ESC |
N/A |
|
|
Non-updateable; SC has no modes that will give any timing increase. |
LRP80450 |
SPX Brushless Bullet Reverse |
N/A |
|
|
Non-updateable; SC has no modes that will give any timing increase. |
LRP80500 |
Sphere Brushless ESC |
N/A |
|
|
Non-updateable; SC has no modes that will give any timing increase. |
LRP80705 |
SPX Zero |
|
|
|
Non-updateable; Zero timing when power profile is set to 0. Red LED will flash in neutral to indicate zero timing |
LRP80905 |
LRP SXX Comp V2 |
1.3,1.5 |
|
|
Mode 3 timing must be set to "0" signified by blinking blue LED in neutral |
LRP809055 |
LRP SXX TC spec V2 |
1.3,1.5 |
|
|
Mode 3 timing must be set to "0" signified by blinking blue LED in neutral |
LRP80910 |
SXX Stock Spec Brushless |
N/A |
|
|
Non-updateable. Mode 3 timing must be set to "0" signified by blinking blue LED when in neutral. |
LRP80915 |
SXX Stock Spec V2 |
4.2,4.4 |
|
|
Desc: For Spec zero timing mode, both mode 2 (torque) and mode 3(timing) must be set to zero. Blue LED will blink in neutral |
LRP80999 |
SXX Mod and Stock Upgrade board |
V 3.1 |
|
|
Zero timing-BLUE LED flashing |
Maclan |
(SKU) MCL2003 |
MMax Pro MCL2003 |
V2.4 |
Hobby Authority Distribution / Maclan |
|
Alternating blue and orange LEDs, 1.00 seconds/cycle. Non-Timing operation: Use Pro Link programming card to set Run Mode to Race Blinky. |
MCL2003 |
MMax Pro |
A3.0 |
Hobby Authority Distribution / Maclan |
|
Alternating blue and orange LEDs, 1.00 seconds/cycle How to Activate Non-Timing Operation: Use Pro Link programming card to set "Run Mode" to "Race Blinky". |
MCL2005 |
MMax Pico |
B3.1 |
Hobby Authority Distribution / Maclan |
|
Alternating blue and orange LEDs 1.00 cycles/second How to Activate Non-Timing Operation: Always in non-timing mode. |
MCL2010 |
M32t Pico 100 |
F21.11 |
Hobby Authority Distribution / Maclan |
|
Alternating blue and orange LEDs, 1.00 seconds/cycle. Non-Timing operation: Select any profile using Maclan Panel PC software, Pro Link or Phone App |
MCL2011 |
M32r Pro 160 |
E21.20 |
Hobby Authority Distribution / Maclan |
|
Alternating blue and orange LEDs, 1.00 seconds/cycle. Non-Timing operation: Select profile #1, #2, or #7 using Maclan Panel PC software, Pro Link or Phone App |
Motiv |
MOV0105 |
Incite Pro 160 |
MI-V.002 |
|
|
Blue LED 0.66 seconds/flash How to Activate Non-Timing Operation: Use USB Link to set “Timing Boost” and “Turbo Timing” to 0deg. |
Muchmore Racing Co., Ltd. |
8809821046592 |
Fleta Euro |
V1.40 |
Muchmore Racing Co., Ltd. |
|
Green LED 0.25 seconds/flash How to Activate Non-Timing Operation: Not applicable; always in non-timing mode. |
8809821051350 |
Fleta Euro V2 High Current BEC Version ME-FLEV2H |
Blinky V3.3_EV2 |
Muchmore Racing Co., Ltd. |
|
Green LED 0.96 seconds/flash How to Activate Non-Timing Operation: Not applicable; always in non-timing mode. |
ME-FLP2K1S |
Fleta Pro V2 1S |
Blinky V1.5R |
Muchmore Racing Co., Ltd. |
|
Green LED 0.26 seconds/flash How to Activate Non-Timing Operation: Not applicable; always in non-timing mode. |
ME-FLPKV3 |
Muchmore Fleta Pro V3 |
8809821052814 |
Muchmore Racing Co., Ltd. |
Details |
Green LED 0.25 seconds flashing indicates Non-Timing |
ORCA |
ES18OE12-4S |
OE1 #ES18OE12-4S |
Version4.2 |
ORCA America-About RC Racing |
|
Blue LED 0.60 seconds/flash How to Activate Non-Timing Operation: Use Program Card to activate "BLINKY MODE". |
ES18OE12-4S |
ORCA OE1 |
Version 6.0 |
ORCA America-About RC Racing |
|
Blue LED blinks when properly programmed using program card. Program card must be updated using Micro SD. |
ES19OE1011S |
OE101s |
Version3.0 |
ORCA America-About RC Racing |
|
Blue LED 0.60 seconds/flash How to Activate Non-Timing Operation: Use Program Card to activate "BLINKY MODE". |
ES19OE1012S |
OE101 |
Version 3.0 |
ORCA America-About RC Racing |
|
Blue LED 0.60 seconds/flash How to Activate Non-Timing Operation: Use Program Card to activate "BLINKY MODE". |
ES19OE1012S |
ORCA OE101 |
Version 5.0 |
ORCA America-About RC Racing |
|
LED blinks Blue. Program Card MUST be used to set Blinky and check. Program Box must be updated to current version using Micro SD card. Update program available on ORCA website |
ES19OE11-2S |
OE1-1S |
Version3.0 |
ORCA America-About RC Racing |
|
Blue LED 0.60 seconds/flash How to Activate Non-Timing Operation: Use Program Card to activate "BLINKY MODE". |
ES19OE11-2S |
ORCA OE1-1S |
Version 6.0 |
ORCA America-About RC Racing |
|
LED blinks Blue. Program Card MUST be used to set Blinky and check. Program Box must be updated to current version using Micro SD card. Update program available on ORCA website |
ES201BP1001 |
BP1001 BlinkyPro ESC |
Version 2.2 |
ORCA America-About RC Racing |
|
LED will blink Blue. No Program Card needed as this is a Non-Timing ONLY ESC |
ES22OE1_WLE |
ORCA OE1WLE (Worlds Edition) |
Version 6.3 |
ORCA America-About RC Racing |
|
Blue LED will blink when in zero timing mode. Set the ESC under Blinky mode Menu utilizing Program Card |
ES22TOTEM2S |
Totem Stock Spec ESC |
3.1 Software |
United Sino Enterprises Ltd |
|
Blinking Blue LED when set |
ES22TOTEM2S |
Totem Brushless Pro |
Version 3.2 -**NEW** - Approved 10/05/2023 |
ORCA America-About RC Racing |
|
LED blinks Blue. Program Card MUST be used to set Blinky and check. Program Box must be updated to current version using Micro SD card. Update program available on ORCA website |
ES23OE11SM2 |
ORCA OE1-1S Mark II |
Version 7.0 |
ORCA America-About RC Racing |
|
LED blinks Blue. Program Card MUST be used to set Blinky and check. Program Box must be updated to current version using Micro SD card. Update program available on ORCA website |
ES23TOTEM1S |
Totem 1S Brushless Pro |
3.1 |
ORCA America-About RC Racing |
|
LED blinks Blue. Program Card MUST be used to set Blinky and check. Program Box must be updated to current version using Micro SD card. Update program available on ORCA website |
ES24OE1MKII |
OE1 Mark II |
Version 7.0 - Updated 1-18-25 |
ORCA America-About RC Racing |
Details |
LED blinks Blue when timing and turbo are off. Program Card MUST be used to set Blinky and check. Program Box must be updated to current version using Micro SD card. Update program available on ORCA website |
ES25OE1WLEB |
OE1 WLEB Brushless ESC - Blinky Only |
V7.0 |
ORCA America-About RC Racing |
|
Purple LED Blinking |
OES810V3 |
ORCA Vritra VX3 |
4.2- 140823A |
ORCA America-About RC Racing |
|
Blue LED, .36 seconds /flash Non timing: set timing at blinky or timing at 0 and turbo timing at OFF |
OES833VG, OES832VR |
R32 |
21.11.170316C |
ORCA America-About RC Racing |
|
Blue LED 0.60 seconds/flash How to Activate Non-Timing Operation: Use Program Card to set "1:Program" to "BLINKY MODE". |
OES863OX, OES861XB |
R32X |
11.12.171009A |
ORCA America-About RC Racing |
|
Blue LED 0.59 seconds/flash How to Activate Non-Timing Operation: TBD Use Program Card to activate |
OES920V1 |
ORCA Vrita VX3 1S |
4.2- 140823A |
ORCA America-About RC Racing |
|
Blue LED, 0.32 seconds/flash. Set"S1:Timng Start" to "Blinky", or "S2: Timing" to "0" and "S5: Turbo Timing" to "Off" |
Pro Performance |
XSC150P |
XSC150P |
XSC150P |
Pro Performance RC |
|
Blue LED 0.66 seconds/flash How to Activate Non-Timing Operation: Use LCD Program Card to set "T1: BOOST TIMING" and T4: TURBO TIMING" to zero. |
R1Wurks |
|
Model 120A.1S |
V1.02_000000 |
R 1 Brushless Motor Lab LLC |
|
Blue LED 0.66 seconds/flash. Non-Timing use Programming Box to set "D1: Bosst Timing" and "E1: Turbo Timong" to zero |
040013 |
Digital-3 Super Stock |
V1.020 |
R 1 Brushless Motor Lab LLC |
|
Green LED rapidly flashing followed by pause, repeats. How to Activate Non-Timing Operation: Use WIFI adapter to set Boost to OFF and Smooth Start Rate and Smooth Start Range to Zero.. |
120A 2s |
R1Wurks Series 120A 2s |
V1.02_000000 |
R 1 Brushless Motor Lab LLC |
|
Blue LED 0.66 seonds/flash Non timing: Programming Box set "D1:Boost Timing" and "E1: Turbo Timing" to zero |
40007 |
Digital 3 |
V1.020 |
R 1 Brushless Motor Lab LLC |
|
Green LED rapidly flashing followed by pause, repeats. How to Activate Non-Timing Operation: Use WIFI adapter to set Boost to OFF and Smooth Start Rate and Smooth Start Range to Zero.. |
R1LCG80 |
R1 Super LCG80 |
B418202 |
R 1 Brushless Motor Lab LLC |
|
Use program box to set "Boost timing" and "Turbo Timing" to zero. Green LED, 0.4 second/flash |
RC OMG |
DR-160AX4 |
OMG Polaris - 160A |
V160A02203SL42000s |
RC OMG |
|
0 Boost mode active = Blue LED blinks. LED Steady if timing or boost present. |
REDS Racing |
SPCO 0007 |
TX2 |
B398202 |
Reds Racing |
|
Green LED 0.42 seconds/flash How to Activate Non-Timing Operation: Use Program Box to set Mode to Stock. |
SPCO 0012 |
ZX Pro 160A |
V4.00_000000 |
Reds Racing |
|
Blue LED 0.66 seconds/flash How to Activate Non-Timing Operation: Use LCD Program Card to set ?T1:BOOST TIMING? and ?T4:TURBO TIMING? to 0 degrees. |
SPCO0016 |
REDS ZX PRO 160A 1/10 GEN2 420404 |
V160A02203SL |
REDS Racing SRL |
|
Blue blinking LED |
SPCO0018, SPCO0019 (With Ext. Bluetooth Module) |
REDS ZX PRO 160A 1/10 GEN3 - External Bluetooth |
v160a02203sl421400 |
REDS Racing SRL |
Details |
Blue LED will blink when in |
TX120A |
REDS Racing Model TX120A (SKU) SPCO 0001 |
B398107 |
REDS Racing SRL |
|
Non Timing Mode: Use program box to set Mode to Stock, or set Boost Timing to zero and Turbo Timing to zero |
Reedy |
27000, 27001 |
Black Box 410R |
V2.9 |
Associated Electrics / REEDY |
|
Greeen LED, 0.22 seconds/flash. Non Timing: Use programmer to set "Misc Control/Run Mode" to Race Blinky |
27002 |
Reedy Blackbox 800Z |
N/A |
Associated Electrics / REEDY |
|
Green LED 0.41 seconds/flash. Always in non timing mode |
27003 |
Reedy Blackbox 1000Z |
N/A |
Associated Electrics / REEDY |
|
Green LED, 0.TBD seconds/flash. Non Timing. Turn ESC on. Press and hold power buttonuntil beeps and green LED blinks. Release power button.five times to step to timing menue. Press and hol power button unti and red LED blinks. If necessary, press and rele |
27004, 27005 |
Reedy Black Box 510R |
B468314 |
Associated Electrics / REEDY |
|
Green LED, 0.42 seconds/flash. Non-Timing Operation: Use Blackbox Programmer2 to set Mode Select to Standard and 5A Timing Level to Level 0. |
27006 |
Blackbox 600Z |
Not Applicable |
Associated Electrics / REEDY |
|
Green LED, 0.41 seconds/flash How to Activate Non-Timing Operation: Not applicable; always in non-timing mode. |
27009, 27010 |
Black Box 510R 1S |
B468101 |
Associated Electrics / REEDY |
|
Green LED, 0.42 seconds/flash How to Activate Non-Timing Operation: Use Blackbox Programmer2 to set ?Mode Select? to ?Standard? and "5A Timing Level" to "Level 0". |
27012 |
Blackbox 600Z-G2 |
11858702 |
Associated Electrics / REEDY |
|
Green LED, 0.42 seconds/flash How to Activate Non-Timing Operation: Not applicable; always in non-timing mode. |
27016 - FW11858509 |
Blackbox 610R |
FW11858509 |
Associated Electrics / REEDY |
|
Green LED Flashes when at neutral. To set to zero timing use program box. In Standard Mode set timing (5A) to level 0; in Expert Mode set BT Soft Pwr (4A), BT Soft Rng (4B), Boost Timing (4D) and Turbo Timing (4H) all to zero |
SANWA |
107A54391A |
Super Vortex Stock |
N/A |
Desoto Racing |
|
Blue LED 0.50 seconds/flash.Non-Timing Operation:Press and hold the Setup Button for 4 seconds or more. The Setup LEDs will flash, indicating the ESC is in Programming Mode. Release the Setup Button Press and release the Setup Button 3 times. The blue LED. ESC must be plugged in to receiver channel 2 only. |
107A54411A |
Super Vortex Gen2 |
G2:V01.02R006 (G2 0102006) |
Desoto Racing |
|
Blue LED 0.50 seconds/flash How to Activate Non-Timing Operation: Use Program Box to set “M04 BOOST” to “OFF”. ESC must be plugged in to receiver channel 2 only. |
SMC |
(SKU) RF-120-2S |
RF-120-2S |
B478105 |
Superior Matching Concepts |
|
Green LED, 0.41 seconds/flash. Non-Timing Operation: Use Program Box to set Boost Timing and Turbo Timing to zero |
(SKU) RF120V2-2-3S |
RF-120V2-3S |
B478105 |
Superior Matching Concepts |
|
Green LED, 0.41 seconds/flash. Non-Timing Operation: Use Program Box to set Boost Timing and Turbo Timing to zero. |
RF-120-1S |
Model RF-120-1S |
B478201 |
Superior Matching Concepts |
|
Green LED, 0.41 seconds/flash. Use program box to set "Boost Timing" and "Turbo Timing" to zero |
RF-120-2S |
Model RF-120-2S |
B478202 |
Superior Matching Concepts |
|
Green LED 0.41 seconds/flash. Non Timing: Use programbox to set |
RF-170-1S |
RF-170-1S |
B478202 |
Superior Matching Concepts |
|
Green LED, 0.41 seconds/flash. How to Activate Non-Timing Operation: Use Program Box to set 'Boost Timing' and 'Turbo Timing' to zero. Use Program Box to set 'Boost Timing''and 'Turbo Timing' to zero. |
RF-170-2S |
RF-170-2S |
B478107 |
Superior Matching Concepts |
|
Green LED, 0.41 seconds/flash How to Activate Non-Timing Operation: Use Program Box to set "Boost Timing" and "Turbo Timing" to zero. Use Program Box to set "Boost Timing" and "Turbo Timing" to zero |
Speedzone |
SZESC80 |
Evolution SC80 |
0B538003 |
Speedzone LLC |
|
Green LED 0.42 seconds/flash How to Activate Non-Timing Operation: Use Program Box to set |
Team Cayote |
CREST X - 160A |
Team Cayote CREST X - 160A |
V1.0.6 |
Team Cayote Racing |
|
Mode must be set to Blinky via Bluetooth or Programming Box - Green LED Blinks every 1.3 seconds |
Team Powers |
PRO-C-140A |
TP-RADON/PRO-C |
RS-Code-V1.1.xup |
RC Explorer Company - Team Powers |
|
Blue LED flashes .65 seconds |
TP - Radon/Pro V2 |
Team Powers Radon Pro V2 |
RS-Code-2.1 |
RC Explorer Company - Team Powers |
|
Blue LED0.66 secons/flash. Non-timing: Connect progrsam card to speed control and set the |
TP-Radon Pro V4_2s-c |
Team Powers Radon Pro V4 |
RS-Code-V4.2 |
RC Explorer Company - Team Powers |
|
Blue LED 0.66 seconds/flash How to Activate Non-Timing Operation: Use Program Card to set Boost Timing and Turbo Timing to 0degrees. |
TP-Radon/ProV2-1S-C |
Team Powers Radon Pro V2 1S |
RS-Code-2-2 |
RC Explorer Company - Team Powers |
|
Blue LED 0.66 seconds/flash. Non-Timing: Connect Program Card to speed contol and set the "T1:Timing Boost" and "T6 Turbo Boost" mode to 0. Press update to confirm each setting value. Power down speed control. |
TP-Radon/ProV3-C |
Radon Pro V3 |
RS-Code-V3.1 |
RC Explorer Company - Team Powers |
|
Blue LED 0.66 seconds/flash - Use USB link and PC program to set Boost Timing and Turbo Timing to 0degrees. |
TP-Radon/ProV4_1-C |
Radon Pro V4.1 |
RS-Code-V5.0 |
RC Explorer Company - Team Powers |
|
Details Special Notes: Blue LED 0.66 seconds/flash How to Activate Non-Timing Operation: Use Program Card to set ?T1: BOOST TIMING? and ?T4: TURBO TIMING? to 0degrees. |
TP-XPS |
Pro-C-V1.2 ESC Hardware Ver. 1.2 |
V0 |
|
|
Zero timing mode indicated by BLINKING Green LRD at neutral. ESC not firmware updateable |
TP-XPS |
EL-C40A ESC Hardware Ver. 1.2 |
V0 |
|
|
Zero timing mode indicated by BLINKING green LED at neutral. ESC not firmware updateable |
TP-XPS/Sport |
Sport-C-70 ESC Hardware Ver. 1.2 |
V0 |
|
|
Zero timing mode indicated by BLINKING green LED at neutral. ESC not firmware updateable. |
TPR-MS-Radon-V2BT |
Mini Spec Radon V2BT 2S (105A) Speed Control (External Bluetooth) |
|
RC Explorer Company - Team Powers |
Details |
Connect the speed control to mobile phone(Android) through the bluetooth device and set the boost timing or turbo timing value to 0 value, then press |
TPR-Radon/ProV5BT-1s |
Radon Pro V5BT 1S (200A) - supprt Bluetooth |
RS-Code V. |
Team Power Products |
|
Connect Speed Control to mobile device. Set boost timing / turb to 0 then press save. Blue LED flash every 0.5s at neutral |
TPRRANDONV5BT |
Radon Pro V5BT 160A 2S Version Only |
v160a02203sl42020j |
RC Explorer Company - Team Powers |
|
Set the boost timing and turbo timing to 0 Blue Blinking LED every 0.5S |
Team Trinity |
TEP0003 |
MX10 Pro |
RS-Code-4.0 |
TRINCORP.LLC |
|
Flashing Blue LED on switch button. How to activate non-timing operation: Set to stock profile and zero timing, zero turbo with program box. |
Team Zombie |
E-TZ-01 |
Team Zombie E-TZ-01 |
V160A02203SL420800 |
Team Zombie / Hoomark Limited |
|
Zero Timing set via bluetooth module. Boost & Timing set to zero degrees = non-timing mode. Blue LED blinks twice then off then blinks twice then off in succession indicates zero timing mode |
Tekin |
TT1156 |
RS Gen 3 |
291 |
Tekin, Inc. |
|
LEDs 3 and 5 flash rapidly. How to Activate Non-Timing Operation: Press MODE button five times, then press INCR button repeatedly until only one LED is lit. |
TT1157 |
RS Gen 3 Spec |
291 |
Tekin, Inc. |
|
LEDs 3 and 5 flash rapidly. How to Activate Non-Timing Operation: Press MODE button five times, then press INCR button repeatedly until only one LED is lit. |
TT1158 |
RSX |
250 |
Tekin, Inc. |
|
Zero timing locked SPEC mode- LED's 3, 4, and 5 flash for ROAR events. Unlocked zero timing is LED's 3, and 5 flashing |
TT1159 |
RSX Pro |
291 |
Tekin, Inc. |
|
LEDs 3 and 5 flash rapidly. How to Activate Non-Timing Operation: Press MODE button five times, then press INCR button repeatedly until only one LED is lit. |
TT1160 |
RS Pro Black Edition |
291 |
Tekin, Inc. |
|
LEDs 3 and 5 flash rapidly. How to Activate Non-Timing Operation: Press MODE button five times, then press INCR button repeatedly until only one LED is lit. |
TT1161 |
RS Pro Black Edition 1S |
291 |
Tekin, Inc. |
|
LEDs 3 and 5 flash rapidly. How to Activate Non-Timing Operation: Press MODE button five times, then press INCR button repeatedly until only one LED is lit. |
TT1162 |
TEKIN RS Gen 3 1S |
V291 |
Tekin, Inc. |
|
LEDs 3 5 or LEDs 3 4 5 in Locked Mode |
Trinity/Horizon Hobby |
TEP0013 |
MX10 1/10 GEN 2 200A ESC |
|
Horizon Hobby, Inc. |
Details |
Blinky Mode set by Bluetooth Module / Flashing Blue Light when in Blinky Mode |